Products
-
Nucleic Acid Horizontal Electrophoresis Cell DYCP-44N
DYCP-44N is used for PCR samples’ DNA identification and separation. Its unique and delicate mould design makes it convenient to operate. It has 12 special Marker holes for loading samples, and it is suitable for 8-channel pipette to load sample. DYCP-44N electrophoresis cell consists of main tank body (buffer tank), lid, comb device with combs, baffle plate, gel delivering plate. It is able to adjust the level of electrophoresis cell. It is especially suitable for fast identifying, separating DNA of many samples of PCR experiment. DYCP-44N electrophoresis cell has many features that make casting and running the gels simple and efficient. The baffle boards provides tape-free gel casting in the gel tray.
-
Nucleic Acid Horizontal Electrophoresis Cell DYCP-44P
DYCP-44P is used for PCR samples’ DNA identification and separation.Its unique and delicate mould design makes it convenient to operate. It has 12 special Marker holes for loading samples, and it is suitable for 8-channel pipette to load sample. It is able to adjust the level of electrophoresis cell.
-
Cellulose Acetate Film Electrophoresis Cell DYCP-38C
DYCP-38C is used for paper electrophoresis, cellulose acetate membrane electrophoresis and slide electrophoresis. It consists of lid, main tank body, leads, adjusting sticks. Its adjusting sticks for different size of paper electrophoresis or cellulose acetate membrane (CAM) electrophoresis experiments. DYCP-38C has one cathode and two anodes, and can run two lines of paper electrophoresis or cellulose acetate membrane (CAM) at the same time. The main body is moulded one, beautiful appearance and no leakage phenomenon.It has three pieces of electrodes of platinum wire. The electrodes are made by pure platinum(the purity quotient of the noble metal ≥99.95%) which have the features of corrosion resistance of electroanalysis and withstand high temperature. The function of electric conduction is very good.The continuous working time of 38C ≥ 24 hours.
-
2-D Protein Electrophoresis Cell DYCZ-26C
DYCZ-26C is used for 2-DE proteome analysis, which needs WD-9412A to cool the second dimension electrophoresis. The system is injection molded with high transparent poly-carbonate plastic. With the special gel casting, it makes the gel casting easy and reliable. Its special balance disc keeps the gel balance in first dimension electrophoresis. Dielectrophoresis can be finished in one day, saving time, lab materials and space.
-
DNA Sequencing Electrophoresis Cell DYCZ-20G
DYCZ-20G is used for DNA sequencing analysis and DNA fingerprinting analysis, differential display and SSCP research. It is researched and designed by our company, which is the only DNA sequence analysis electrophoresis cell with double plates in the market; with high repeatable experiments, it greatly improves the work efficiency. It is a classic choice for marking experiment.
-
Modular Dual Vertical System DYCZ-24F
DYCZ-24F is used for SDS-PAGE, Native PAGE electrophoresis and the second dimension of 2-D electrophoresis.With the function of casting gel in original position, it is able to cast and run the gel at the same place, simple and convenient to make gels, and save your precious time. It can run two gels at once and save buffer solution. Its power source will be switched off when user opens the lid. Its built-in heat exchanger can eliminate the heat produced during the running.
-
Modular Dual Vertical System DYCZ – 25D
DYCZ 25D is the update version of DYCZ – 24DN. It’s gel casting chamber is installed in the main body of electrophoresis apparatus directly that is able to cast and run the gel at the same place. It can place two different sizes of gel. Its injection molded constriction with high strong poly carbonate materials makes it solid and durable. It’s easy to observe gel through high transparent tank. This system has heat dissipation design to better avoid heating during running.
-
Trans-Blotting Electrophoresis Cell DYCP – 40E
DYCZ-40E is used For fast transferring the protein molecule from the gel to membrane like nitrocellulose membrane. It is Semi-dry blotting and no need buffer solution. It can transfer very fast with high efficiency and good effect. With safe plug technique, all the exposed parts are insulated. The transfer bands are very clear.
-
Trans-Blotting Electrophoresis Cell DYCZ – 40D
DYCZ-40D is used for transferring the protein molecule from the gel to membrane like nitrocellulose membrane in the Western Blot experiment. It is made of high quality transparent polycarbonate with platinum electrodes. Its seamless, injection-molded transparent buffer tank prevents leakage and breakage. It can transfer very fast with high efficiency and good effect. It is compatible with the lid and buffer tank of DYCZ-24DN tank.
-
Trans-Blotting Electrophoresis Cell DYCZ – 40F
DYCZ-40F is used for transferring the protein molecule from the gel to membrane like nitrocellulose membrane in the Western Blot experiment. It is made of high quality transparent polycarbonate with platinum electrodes. Its seamless, injection-molded transparent buffer tank prevents leakage and breakage. It can transfer very fast with high efficiency and good effect. The customized blue ice pack as cooling unit can help the rotor magnetic stirring, better for heat dissipation. It is compatible with the lid and buffer tank of DYCZ-25E tank.
-
Trans-Blotting Electrophoresis Cell DYCZ–40G
DYCZ-40G is used for transferring the protein molecule from the gel to membrane like nitrocellulose membrane in the Western Blot experiment. It is made of high quality transparent polycarbonate with platinum electrodes. Its seamless, injection-molded transparent buffer tank prevents leakage and breakage. It can transfer very fast with high efficiency and good effect. It is compatible with the lid and buffer tank of DYCZ-25D tank
-
DYCZ-24DN Notched Glass Plate (1.0mm)
Notched glass plate (1.0mm)
Cat.No.:142-2445A
Notched glass plate sticked with spacer, the thickness is 1.0mm, for use with DYCZ-24DN system.
Vertical gel electrophoresis systems are primarily used for nucleic acid or protein sequencing. Achieve precise voltage control using this format that forces charged molecules to travel through the casted gel since it is the only buffer chamber connection. The low current used with the vertical gel systems does not require buffer to be recirculated. DYCZ – 24DN mini dual vertical electrophoresis cell utilizes protein and nucleic acid analytical tools for application within all aspects of life science research, ranging from purity determination to analysis protein.